SAC-10 Plus Triton
Semi-anechoic 10,0 m EMC chamber with multiple test axes
Semi-anechoic 10,0 m EMC chamber with multiple test axes
The SAC-10 Plus Triton is Frankonia’s full compliant and state-of-the-art EMC testing solution with multiple test axes at 10,0 m, 5,0 m & 3,0 m test distance with a Quiet Zone (QZ) of ø3,0 m. The innovative polygonal shape along with its optimized absorber layout allows for a usage of multiple axes having a ready test setup for emission and immunity tests.
The benefits of its multiple test axes allow our customers to measure all required EMI/EMS procedures without the need to modify the test environment or the test setup. The test equipment and instruments can remain connected in the chamber. The absorber areas necessary for each test can be provided with guided movement and are stored in defined parking positions. Due to the reproducible test setup, the SAC-10 Plus Triton offers outstanding performance for NSA, SVSWR and FU and real time savings.
Overview |
EMI | CISPR 16-1-4 and ANSI C63.4, full compliant |
EMS | IEC/EN 61000-4-3, full compliant |
Test distance | 3,0m, 5,0m and 10,0m |
Volume | ø3,0 m |
Special | Multi-axes 10,0 m chamber |
Multiple test axis option (1x 10,0 m and 2x 3,0 m test distance)
10,0 m, 5,0 m & 3,0 m measuring distances with a Quiet Zone of ø3,0 m
Full compliant EMI/EMS
Space-saving and compact chamber design with polygonal shape
Floor absorbers, and antennas remain connected in the chamber
Reproducibility and stable performance
Time-saving test setup with improved workflow and efficiency
Excellent performance in a compact chamber size
Ingenious lining with long-lasting Frankosorb® non-combustible absorbers
Cost-saving and future-proof investment
Turnkey solution
Frankosorb® optimized hybrid absorber lining with Ferrite F006, H600, and H1000 on the walls, and long-pyramids P2400 absorbers mixed with hybrids on the ceiling
High-performance nano thin-film technology with proven long-term stability
Available material classifications:
non-combustible acc. to DIN EN 13501-1 class A2 – s1 d0, or
hardly inflammable acc. to DIN EN 13501-1 class B (alternative)
Emission
CISPR 11
CISPR 14
CISPR 15
CISPR 25
CISPR 32
MIL-STD 461
Immunity
IEC/EN 61000-4-3
ISO 11452
MIL-STD 461
Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.
Emission
CISPR 16-1-4
and/or ANSI C63.4
Immunity
IEC/EN 61000-4-3
Chamber Type | SAC-10 Plus Triton |
External dimension | 19.205 x 12.080 x 8.325 mm (LxWxH) |
Version | Polygonal shape design with multiple test axis |
Quiet Zone | ø3,0 m |
Turntable | ø3,0 m or ø4,0 m |
Measuring distances | Test axis 1: 10,0 m, 5,0 m and 3,0 m (for emission) Test axis 2: 3,0 m (for emission and immunity) Test axis 3: 3,0 m (for immunity) |
Load capacity | up to 5.000 kg; special turntable systems possible |
Frequency range | 9 kHz/ 30 MHz to 18 GHz or 40 GHz |
With the use of three independent test axis dedicated to each EMI and EMS test, all antennas and floor-absorbers remain connected in the chamber
The Triton works like a regular 10,0 m SAC chamber without any limitations
Thanks to the guided floor absorber arrangement, the test setup preparation time reduces enormously, while reproducibility and quality of each testing remain stable
Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4
Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed
Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0/+6 dB for 12 of 16 test points (75%)
(26 MHz to 18 GHz) – guaranteed