SAC-5 Plus
Semi Anechoic 5m EMC Chamber with dome-shape design
Semi Anechoic 5m EMC Chamber with dome-shape design
The SAC-5 Plus is Frankonia’s full compliant EMC testing solution at 3,0m & 5,0m measuring distance with a Quiet Zone (QZ) up to ø3,0 m. It is adapted for full compliant emissions and immunity testing. The innovatively shaped roof, called dome design, with its optimized absorber layout leads to minimized reflections and offers outstanding performance for NSA, SVSWR and FU.
Cost-efficient and high-performance solution for a 5,0 m measuring distance
Full compliant EMI/EMS
Adapted steel structure and optimized RF-shielding with dome-shaped roof
Upgradeable for E-Drive (load machine, BlueBox, battery test system)
Ingenious absorber lining with Frankosorb®
Outstanding performance with long-lasting Frankosorb®
non-combustible absorbers
Turnkey solution
Emission
CISPR 11
CISPR 14
CISPR 15
CISPR 25
CISPR 32
MIL-STD 461
Immunity
IEC/EN 61000-4-3
ISO 11452
MIL-STD 461
Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.
Emission
CISPR 16-1-4
and/or ANSI C63.4
Immunity
IEC/EN 61000-4-3
Chamber Type | SAC-5 Plus | SAC-5 Plus LÂ |
External dimension | 12.680 x 7.730 x 6.300 mm (LxWxH) | 12.680 x 8.180 x 6.300 mm (LxWxH) |
Version | Dome design | |
Quiet Zone | ø2,0 m | ø3,0 m |
Measuring distances | 5,0 m and 3,0 m | |
Load capacity | up to 5,0 tons; special turntable systems possible | |
Frequency range | 9 kHz/ 30 MHz to 18 GHz (option 40 GHz) |
Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4
Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed
Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed
Copyrighted Image