Overview
EMICISPR 16-1-4 and ANSI C63.4, full compliant
EMSIEC/EN 61000-4-3, full compliant
Test distance3,0m
Volumeup to ø2,0 m
SpecialPerformance dome shape design

The SAC-3 Plus is Frankonia’s most versatile full compliant EMC testing solution at 3,0 m measuring distance with a Quiet Zone (QZ) up to ø2,0 m. It is adapted for full compliant emission and immunity testing. The innovatively shaped roof, called dome design, with its optimized absorber layout leads to minimized reflections and offers outstanding performance for NSA, SVSWR and FU.

Features

Cost-efficient and high-performance solution for a 3,0 m measuring distance

Full compliant EMI/EMS

Adapted steel structure and optimized RF-shielding with dome-shaped roof

Upgradeable for E-Drive (load machine, BlueBox, battery test system)

Ingenious absorber lining with Frankosorb®

Outstanding performance with long-lasting Frankosorb®

non-combustible absorbers

Turnkey solution

Typical Product Standards

Emission

CISPR 11

CISPR 14

CISPR 15

CISPR 25

CISPR 32

MIL-STD 461

Immunity

IEC/EN 61000-4-3

ISO 11452

MIL-STD 461

Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.

Typical Verification Standards

Emission

CISPR 16-1-4

and/or ANSI C63.4

Immunity

IEC/EN 61000-4-3

Typical Specifications

Chamber Type SAC-3 Plus S SAC-3 Plus M SAC-3 Plus L SAC-3 Plus
External dimension 8.480 x 6.530 x 6.000 mm (LxWxH) 8.780 x 6.530 x 6.000 mm (LxWxH) 9.230 x 6.530 x 6.000 mm (LxWxH) 9.680 x 6.530 x 6.000 mm (LxWxH)
Quiet Zone ø1,2 m ø1,5 m ø2,0 m ø2,0 m
Load capacity up to 5,0 tons; special turntable systems possible
Frequency range 9 kHz/ 26 MHz to 18 GHz (option 40 GHz)

Performance & Compliance

Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4

Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

Full compliant immunity (EMS) according to IEC/EN 61000-4-3

Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed