SAC-10 Plus

Semi Anechoic 10m EMC Chamber in compact shape

Overview
EMICISPR 16-1-4 and ANSI C63.4, full compliant
EMSIEC/EN 61000-4-3, full compliant
Test distance3,0 m, 5,0 m and 10,0 m
Volumeø3,0 m
SpecialCompact 10 m chamber

The SAC-10 Plus is Frankonia’s full compliant and state-of-the-art EMC testing solution at 10m, 5m & 3m measuring distances with a Quiet Zone (QZ) of ø4,0m. The innovative polygonal shape along with its optimized absorber layout is a space-saving, cost-saving and efficient solution with a single test axis. The SAC-10 Plus is fully compliant for emission tests validated according to CISPR 16-1-4, as well as full compliant for immunity tests according to IEC/EN 61000-4-3. In addition, the SAC-10 Plus is Frankonia’s most compact 10m chamber available to meet CISPR 16-1-4 and ANSI C63.4 test site requirements.

Features

10,0 m, 5,0 m & 3,0 m measuring distances with a Quiet Zone of ø3,0 m or ø4,0 m

Full compliant EMI/EMS

Ingenious absorber lining with Frankosorb®

Outstanding performance with long-lasting Frankosorb®

non-combustible absorbers

Cost-saving and future-proof investment

Space-saving chamber in polygonal shape

Turnkey solution

Typical Product Standards

Emission

CISPR 11

CISPR 14

CISPR 15

CISPR 25

CISPR 32

MIL-STD 461

Immunity

IEC/EN 61000-4-3

ISO 11452

MIL-STD 461

Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.

Typical Verification Standards

Emission

CISPR 16-1-4

and/or ANSI C63.4

Immunity

IEC/EN 61000-4-3

Typical Specifications

Chamber SAC-10 Plus
External dimension 19.205 x 12.080 x 8.325 mm (LxWxH)
Version Polygonal shape design with single test axis
Quiet Zone  ø3,0 m or ø4,0 m
Turntable ø3,0 m or ø4,0 m
Measuring distances 10,0 m, 5,0 m and 3,0 m
Load capacity up to 5,0 tons; special turntable systems possible
Frequency range 9 kHz/ 30 MHz to 18 GHz (option 40 GHz)

Performance & Compliance

Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4

Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

Full compliant immunity (EMS) according to IEC/EN 61000-4-3

Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points
(26/ 80 MHz to 18 GHz) – guaranteed