More products
show

SAC-10 Plus

Semi-anechoic 10,0 m EMC chamber in compact shape

The SAC-10 Plus is Frankonia’s full compliant and state-of-the-art EMC testing solution at 10,0 m, 5,0 m & 3,0 m test distance with a Quiet Zone (QZ) of ø3,0 m. The innovative polygonal shape along with its optimized absorber layout is a space-saving, cost-saving and efficient solution with a single test axis. The SAC-10 Plus is fully compliant for emission tests validated according to CISPR 16-1-4, as well as full compliant for immunity tests according to IEC/EN 61000-4-3. In addition, the SAC-10 Plus is Frankonia’s most compact 10,0 m chamber available to meet CISPR 16-1-4 and ANSI C63.4 test site requirements.

Overview
EMICISPR 16-1-4 and ANSI C63.4, full compliant
EMSIEC/EN 61000-4-3, full compliant
Test distance3,0 m, 5,0 m and 10,0 m
Volumeø3,0 m
SpecialCompact 10,0 m chamber

Features

Compact 10,0 m chamber

10,0 m, 5,0 m & 3,0 m test distance with a QZ of ø3,0 m

Full compliant EMI/EMS

Space-saving and compact chamber design with polygonal shape

Excellent performance in a compact chamber size

Ingenious lining with long-lasting Frankosorb® non-combustible absorbers

Cost-saving and future-proof investment

Turnkey solution

Absorbers

Frankosorb® optimized hybrid absorber lining with Ferrite F006, H600, and H1000 on the walls, and long-pyramids P2400 absorbers mixed with hybrids on the ceiling

High-performance nano thin-film technology with proven long-term stability

Available material classifications:
non-combustible acc. to DIN EN 13501-1 class A2 – s1 d0, or
hardly inflammable acc. to DIN EN 13501-1 class B (alternative)

Typical Product Standards

Emission

CISPR 11

CISPR 14

CISPR 15

CISPR 25

CISPR 32

MIL-STD 461

Immunity

IEC/EN 61000-4-3

ISO 11452

MIL-STD 461

Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.

Typical Verification Standards

Emission

CISPR 16-1-4

and/or ANSI C63.4

Immunity

IEC/EN 61000-4-3

Typical Specifications

Chamber SAC-10 Plus
External dimension 19.205 x 12.080 x 8.325 mm (LxWxH)
Version Polygonal shape design with single test axis
Quiet Zone  ø3,0 m
Turntable ø3,0 m or ø4,0 m
Measuring distances 10,0 m, 5,0 m and 3,0 m (for emission and immunity)
Load capacity up to 5.000 kg; special turntable systems possible
Frequency range 9 kHz/ 30 MHz to 18 or 40 GHz

Performance & Compliance

Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4

Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

Full compliant immunity (EMS) according to IEC/EN 61000-4-3

Deviation FU 0/+6 dB for 12 of 16 test points (75%)
(26 MHz to 18 GHz) – guaranteed