SAC-10/P Pyramid

Semi Anechoic 10m EMC Chamber with Long-pyramid P2400 Absorbers

Overview
EMICISPR 16-1-4 and ANSI C63.4, full compliant
EMSIEC/EN 61000-4-3, full compliant
Test distanceup to 10,0m
Volumeø3,0 m up to ø6,0 m
SpecialP2400 Long-pyramid Absorbers

The SAC-10/P chambers are Frankonia’s full compliant and customizable EMC testing solutions at 10,0m measuring distance offering various sizes of the Quiet Zone (QZ). Due to the high grade of customization reflecting the demands of our customers, this semi-anechoic chamber is adaptable in size and offers several configuration possibilities. The innovative concept with its impressionable absorber layout achieves exceptional performance for emission and immunity testing.

Features

Unique Frankosorb® P2400 Pyramid Absorbers

Full compliant EMI/EMS

Highly customizable solution for any kind of EMC testing

and limitless integration of individual applications

Adjustable chamber size, characteristics and configuration

due to different EUT requirements

Advanced absorber lining with long-lasting Frankosorb® absorbers

(Frankonia technology)

Specialized for ‘out-of-the-range’ EMC test environments

Turnkey solution

Typical Product Standards

Emission

CISPR 11

CISPR 12

CISPR 14

CISPR 15

CISPR 25

CISPR 32

MIL-STD 461

Immunity

IEC/EN 61000-4-3

ISO 11451

ISO 11452

MIL-STD 461

RS101, RS102

RS103

Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.

Typical Verification Standards

Emission

CISPR 16-1-4

and/or ANSI C63.4

Immunity

IEC/EN 61000-4-3

Typical Specifications

Chamber Type SAC-10-3/P SAC-10-4/P SAC-10-5/P SAC-10-6/P
External dimension 21.680 x 13.730 x 8.550 mm (LxWxH) 21.680 x 13.730 x 8.550 mm (LxWxH) 23.480 x 16.580 x 9.000 mm (LxWxH) 24.980 x 17.180 x 9.000 mm (LxWxH)
Quiet Zone at 3,0m ø3,0 m ø3,0 m ø3,0 m ø3,0 m
Quiet Zone at 5,0m ø3,0 m ø4,0 m ø5,0 m ø5,0 m
Quiet Zone at 10,0m ø3,0 m ø4,0 m ø5,0 m ø6,0 m
Load capacity up to 80,0 tons; special turntable systems and dynamometer integration possible
Frequency range 9 kHz/ 26 MHz to 18 GHz (option 40 GHz)

Performance & Compliance

Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4

Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

Full compliant immunity (EMS) according to IEC/EN 61000-4-3

Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points
(26/ 80 MHz to 18 GHz) – guaranteed