AVTC

Automotive Component and Vehicle Testing Chamber

Overview
EMICISPR 16-1-4 and ANSI C63.4, full compliant
CISPR 25 and CISPR 12, full compliant
EMSIEC/EN 61000-4-3, full compliant
Test distanceup to 10,0m
VolumeØ3,0m (typical)
SpecialHybrid or Pyramid Absorbers
ECE R10.5Full compliant at 3,0 m with dynamometer

The AVTC is Frankonia’s automotive anechoic chamber solution at typical 3,0m measuring distance offering a Quiet Zone (QZ) of ø3,0m. It is adapted for radiated emissions and immunity tests on vehicles and components as well as for commercial product tests.

The AVTC-L is the extended version of Frankonia’s automotive anechoic chamber solution at 3,0m and 5,0m measuring distance offering a Quiet Zone (QZ) of ø3,0m. The AVTC-XL offer the integration of a normal range dynamometer.

Features

Automotive component and vehicle tests together

with commercial tests in a single solution

Cost-effective and high-performance solution

for a 3,0 m or 5,0 m measuring distance

Floor-absorberboard for an efficient and fast modification of the test setup

Upgradeable with EDTC components (load machine, BlueBox, battery test system)

Typical Product Standards

Emission

CISPR 11

CISPR 12

CISPR 14

CISPR 15

CISPR 25

CISPR 32

MIL-STD 461

ECE R10.5

Immunity

IEC/EN 61000-4-3

ISO 11451

ISO 11452

MIL-STD 461

RS 101, RS102,

RS103

ECE R10.5

Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.

Typical Verification Standards

Emission

CISPR 16-1-4

and/or ANSI C63.4

Immunity

IEC/EN 61000-4-3

Typical Specifications

Chamber Type AVTC AVTC-L AVTC-XL
External dimension 11.480 x 9.380 x 6.000 mm (LxWxH) 14.780 x 11.480 x 6.300 mm (LxWxH) 16.280 x 12.680 x 6.300 mm (LxWxH)
Quiet Zone at 3,0 m ø3,0 m ø3,0 m ø3,0 m
Quiet Zone at 5,0 m n/a ø3,0 m ø5,0 m
Turntable ø5,0 m ø6,0 m Ø6,7 m dynamometer
Load capacity up to 30,0 tons; special turntable systems and dynamometer integration
Frequency range 9 kHz/ 26 MHz to 18 GHz (option 40 GHz)

Performance & Compliance

Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4

Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

Full compliant immunity (EMS) according to IEC/EN 61000-4-3

Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points (26/ 80 MHz to 18 GHz) – guaranteed

Full compliant emission (EMI) according to CISPR 25 Ed.4

(ALSE verification acc. to the long-wire method recommended)

Full compliant emission (EMI) according to CISPR 12 at 3,0 m

Full compliant immunity (EMS) according to ISO 11452 and ISO 11451

Perfectly meets ECE R10.5 with dynamometer integration