ECU-6, EMC Control Unit
For radiated immunity testing according to IEC/EN 61000-4-3, ISO 11452-2/3/4/5 and MIL-STD 461, RS 103
For radiated immunity testing according to IEC/EN 61000-4-3, ISO 11452-2/3/4/5 and MIL-STD 461, RS 103
DESCRIPTION
The ECU-6 is a central EMC test and control unit, which combines in just one compact box many major test components like signal generator, power meter, directional couplers and relay switching unit, which are needed for EMC tests. That reduces the cabling work and possible cabling mistakes to a minimum. Furthermore it includes general functions like EUT-monitoring and an interlock safety-system. With all the functions described above, the ECU-6 is a real all-rounder, which can be used for many different conducted and radiated immunity tests as well as control unit to switch between EMI-receiver and spectrum analyzer and different measuring antennas without time consuming cabling work. It allows to control and to switch automatically between up to four external amplifiers, all connected to the ECU-3/-6 and up to three different outputs for antennas or coupling devices (CDNs, EM-coupling clamp, BCI-clamps). The integrated signal generator is available to cover the frequency range from 9 kHz to 6 GHz. Amplitude modulation is available with a modulation rate of 1 Hz to 30 kHz and a modulation depth of 0 % to 90 %. Pulse modulation can be switched on with a repetition frequency of 0.1 Hz to 100 kHz and a duty cycle of 1 % – 99 %. In a word, it includes all requirements according to present EMC standards and it is best prepared for possible future changes.
SPECIAL FEATURES
– Conducted immunity tests according to IEC/EN 61000-4-6, 10 kHz – 230 MHz
– BCI-tests according to ISO 11452-4 and MIL-STD 461, CS 114
– Radiated immunity tests according to: IEC/EN 61000-4-3, ISO 11452-2/3/4/5, MIL-STD 461, RS 103
– Automatic switching between up to four external power amplifiers and connected coupling units / antennas
– Automatic switching between up to two EMI-receivers, spectrum analyzers and three different antennas
– Easy integration into any control software by dll-driver
– Integrated interlock safety system
Technical specifications ECU-6 | |
Signal generator | |
Output | 50 Ω, N female |
Output (relay) | 4 x N male |
Frequency range | 9 kHz to 6.5 GHz |
Frequency resolution | 0.001 Hz |
Output level range | -100 dBm to +13 dBm |
Output level resolution | 0.1 dB |
Output level accuracy | ±1 dB max. |
Accuracy (frequency) | ±100 ppm |
Harmonics | < -30 dBc |
Non harmonics | < -55 dBc |
Amplitude modulation | |
Modulation rate | 1 Hz to 20 kHz; resolution 0.1 Hz |
Modulation depth | 0 to 90 %; resolution 1 % |
Modulation waveforms | sinusoidal, triangular, square |
Pulse modulation | |
ON/OFF ratio | typ. 80 dB |
Repetition frequency | 0.1 Hz to 100 kHz |
Duty cycle | 1%-99%; resolution1% |
Frequency modulation | |
Modulation rate | 300 Hz to 300 kHz |
RF-Power Meter | |
Number of channels | 9 |
Frequency Range | 10 kHz – 500 MHz (channel 1,2,9) 100 kHz – 6 GHz (channel 3,4,5,6,7,8) |
Measuring range | -60 dBm to +20 dBm (10 kHz ≤ f ≤ 4 GHz) -45 dBm to +20 dBm (4 GHz < f ≤ 6 GHz) |
Accuracy | ±1 dB (0.5 dB typical) |
Resolution | 0.1 dB |
Max. input level | +27 dBm (= 500 mW) |
VSWR | 1.15 |
EUT-fail input | 2 x TTL/CMOS compatible |
Input resistance | 2.2 kΩ |
Level | TTL / CMos compatible, optical decoupled |
Remote control | |
USB-B | Connection to computer |
GPIB / IEEE488 | Connection to computer |
Ethernet / RJ45 | option |
Display | |
Displayed items | Frequency, Power levels P(forw), P(rev), modulation (4 lines x 16 characters) |
RF-relay switching unit | |
max. power up to 100 MHz | 2000W |
max. power up to 600 MHz | 1000W |
max. power up to 1 GHz | 700W |
max. power up to 3 GHz | 400W |
max. power up to 6 GHz | 300W |
General data | |
Temperature range | 0 to 40°C |
Warm-up time | 15 min. |
Housing | 19”-Subrack or desktop case |
Dimensions (W x H x D) | 449 mm x 177 mm x 580 m |
Weight | approx. 18 kg |
AC input | 100 – 240 VAC, 50 / 60 Hz |
Options | Please download our data sheet for detailled information |