Bulk Current Injection Probe
For tests acc. to ISO 11452-4, MIL-STD-461 and IEC/EN 61000-4-3
For tests acc. to ISO 11452-4, MIL-STD-461 and IEC/EN 61000-4-3
Specifications | |
Frequency range | 1 MHz – 400 MHz |
Input connector | Type N female |
Inner diameter | 120 mm |
Outer diameter | 40 mm |
Width | 40 mm |
Max. core temperature | 90 °C |
Turns ratio | 1:1 |
Primary inductance | 5.1 ÎĽH @ 100 kHz |
Ambient temperature | 0 to 40 °C |
Fastening | 1 Clip |
Input Power rating until core temperature is 90 °C | 90 min @ 70 W (48.45 dBm) 45 min @ 100 W (50 dBm) |
Order number | BCI-CLAMP-2 |
FEATURES
• Meets specifications of ISO 11452-4:2005, MIL-STD-461 and IEC/EN 61000-4-6
• Frequency range from 1 MHz up to 400 MHz
• Designed for automotive BCI testing
• Low insertion loss
DESCRIPTION
The bulk current injection probe, type BCI-CLAMP-2Â is used to inject RF-current into cables of electrical equipment to test the susceptibility against radiated electromagnetic energy. It was designed to meet the specifications of ISO 11452-5:2005 and IEC/EN 61000-4-6 standards for automotive BCI testing with secondary currents of 300 mA and more. The probe can be easily clamped around test conductors and supports cable harness diameters up to 40 mm diameter.