More products
show

SAC-10 Plus Triton

Semi-anechoic 10,0 m EMC chamber with multiple test axes

The SAC-10 Plus Triton is Frankonia’s full compliant and state-of-the-art EMC testing solution with multiple test axes at 10,0 m, 5,0 m & 3,0 m test distance with a Quiet Zone (QZ) of ø3,0 m. The innovative polygonal shape along with its optimized absorber layout allows for a usage of multiple axes having a ready test setup for emission and immunity tests.

The benefits of its multiple test axes allow our customers to measure all required EMI/EMS procedures without the need to modify the test environment or the test setup. The test equipment and instruments can remain connected in the chamber. The absorber areas necessary for each test can be provided with guided movement and are stored in defined parking positions. Due to the reproducible test setup, the SAC-10 Plus Triton offers outstanding performance for NSA, SVSWR and FU and real time savings.

Overview
EMICISPR 16-1-4 and ANSI C63.4, full compliant
EMSIEC/EN 61000-4-3, full compliant
Test distance3,0m, 5,0m and 10,0m
Volumeø3,0 m
SpecialMulti-axes 10,0 m chamber

Features

Multiple test axis option (1x 10,0 m and 2x 3,0 m test distance)

10,0 m, 5,0 m & 3,0 m measuring distances with a Quiet Zone of ø3,0 m

Full compliant EMI/EMS

Space-saving and compact chamber design with polygonal shape

Floor absorbers, and antennas remain connected in the chamber

Reproducibility and stable performance

Time-saving test setup with improved workflow and efficiency

Excellent performance in a compact chamber size

Ingenious lining with long-lasting Frankosorb® non-combustible absorbers

Cost-saving and future-proof investment

Turnkey solution

Absorbers

Frankosorb® optimized hybrid absorber lining with Ferrite F006, H600, and H1000 on the walls, and long-pyramids P2400 absorbers mixed with hybrids on the ceiling

High-performance nano thin-film technology with proven long-term stability

Available material classifications:
non-combustible acc. to DIN EN 13501-1 class A2 – s1 d0, or
hardly inflammable acc. to DIN EN 13501-1 class B (alternative)

Typical Product Standards

Emission

CISPR 11

CISPR 14

CISPR 15

CISPR 25

CISPR 32

MIL-STD 461

Immunity

IEC/EN 61000-4-3

ISO 11452

MIL-STD 461

Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.

Typical Verification Standards

Emission

CISPR 16-1-4

and/or ANSI C63.4

Immunity

IEC/EN 61000-4-3

Typical Specifications

Chamber Type SAC-10 Plus Triton
External dimension 19.205 x 12.080 x 8.325 mm (LxWxH)
Version Polygonal shape design with multiple test axis
Quiet Zone ø3,0 m
Turntable ø3,0 m or ø4,0 m
Measuring distances Test axis 1: 10,0 m, 5,0 m and 3,0 m (for emission)
Test axis 2: 3,0 m (for emission and immunity)
Test axis 3: 3,0 m (for immunity)
Load capacity up to 5.000 kg; special turntable systems possible
Frequency range 9 kHz/ 30 MHz to 18 GHz or 40 GHz

SAC-10 Plus Triton Features

With the use of three independent test axis dedicated to each EMI and EMS test, all antennas and floor-absorbers remain connected in the chamber

The Triton works like a regular 10,0 m SAC chamber without any limitations

Thanks to the guided floor absorber arrangement, the test setup preparation time reduces enormously, while reproducibility and quality of each testing remain stable

Performance & Compliance

Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4

Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

Full compliant immunity (EMS) according to IEC/EN 61000-4-3

Deviation FU 0/+6 dB for 12 of 16 test points (75%)
(26 MHz to 18 GHz) – guaranteed