SAC-3 Square
Semi Anechoic 3,0 m EMC chamber with traditional square design
Semi Anechoic 3,0 m EMC chamber with traditional square design
The SAC-3 Square is Frankonia’s versatile full compliant EMC testing solution at 3,0 m measuring distance with a Quiet Zone (QZ) of ø2,0 m or ø3,0 m. It is adapted for full compliant emission and immunity testing. The SAC-3 in square design offer an innovative concept with its usability, customization, and performance, and therefore represent efficient and economical solutions.
Overview |
EMI | CISPR 16-1-4 and ANSI C63.4, full compliant |
EMS | IEC/EN 61000-4-3, full compliant |
Test distance | 3,0m |
Volume | up to ø3,0 m |
Special | Traditional square design |
Traditional square design
High-performance solution for a 3,0 m measuring distance and QZ from ø2,0 m of up to ø3,0 m
Full compliant EMI/EMS
Immunity floor-absorber storage on trolley‘s in the chamber
Upgradeable for E-Drive (load machine, EMC-BlueBox, battery test system)
Ingenious absorber lining with Frankosorb®
Outstanding performance with long-lasting Frankosorb®
non-combustible absorbers
Useable for automotive and military standard tests
Turnkey solution
Frankosorb® optimized hybrid absorber lining with Ferrite F006, H600 and H1000
High-performance nano thin-film technology with proven long-term stability
Available material classifications:
non-combustible acc. to DIN EN 13501-1 class A2 – s1 d0, or
hardly inflammable acc. to DIN EN 13501-1 class B (alternative)
Emission
CISPR 11
CISPR 14
CISPR 15
CISPR 25
CISPR 32
MIL-STD 461
Immunity
IEC/EN 61000-4-3
ISO 11452
MIL-STD 461
Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.
Emission
CISPR 16-1-4
and/or ANSI C63.4
Immunity
IEC/EN 61000-4-3
Chamber Type | SAC-3 Square | SAC-3 Square L |
External dimension | 9.680 x 6.530 x 6.000 mm (LxWxH) | 10.880 x 6.980 x 6.000 mm (LxWxH) |
Quiet Zone | ø2,0 m | ø3,0 m |
Measuring distances | 3,0 m | |
Load capacity | up to 5.000 kg; special turntable systems possible | |
Frequency range | 9 kHz/ 26 MHz to 18 or 40 GHz |
Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4
Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed
Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0/+6 dB for 12 of 16 test points (75%)
(26 MHz to 18 GHz) – guaranteed