More products
show

SAC-3 / FAC-3 Transformer

Semi and fully anechoic 3,0 m EMC chamber, transformable combination

The SAC-3/FAC-3 Transformer is Frankonia’s full compliant EMC testing solution at 3,0m measuring distance offering semi as well as fully conditions. This special solution focus on conditions with ground plane, as well as FAR conditions for table-top EUT tests with an optimized floor-absorber modification kit. The SAC-3/FAC-3 Transformer chamber is adapted for full compliant emissions and immunity testing with a traditional square design.

Overview
EMICISPR 16-1-4 and ANSI C63.4, full compliant
EMSIEC/EN 61000-4-3, full compliant
Test distance3,0m
Volumeø2,0 m as SAC Chamber
ø1,5 m as FAC Chamber
SpecialTransformable test site from SAC to FAC

Features

Transformable from SAC to FAC test site

Cost-effective and high-performance solution for a 3,0 m measuring distance
SAC setup: QZ of ø2,0 m
FAC setup: QZ of ø1,5 m

Full compliant EMI/EMS

Upgradeable for E-Drive (load machine, BlueBox, battery test system)

Compact chamber design with advanced absorber lining

Outstanding performance with long-lasting Frankosorb® non-combustible absorbers

Turnkey solution

Useable for automotive and military standard tests

Absorbers

Frankosorb® optimized hybrid absorber lining with Ferrite F006, H600 and H1000

High-performance nano thin-film technology with proven long-term stability

Available material classifications:
non-combustible acc. to DIN EN 13501-1 class A2 – s1 d0, or
hardly inflammable acc. to DIN EN 13501-1 class B (alternative)

Typical Product Standards

Emission

CISPR 11

CISPR 14

CISPR 15

CISPR 25

CISPR 32

MIL-STD 461

Immunity

IEC/EN 61000-4-3

ISO 11452

MIL-STD 461

Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.

Typical Verification Standards

Emission

CISPR 16-1-4

and/or ANSI C63.4

IEC/EN 61000-4-22

Immunity

IEC/EN 61000-4-3

IEC/EN 61000-4-22

Typical Specifications

Chamber Type SAC-3 / FAC-3 Transformers
External dimension 9.680 x 6.530 x 6.000 mm (LxWxH)
Quiet Zone  ø2,0 m; height 1,5 m (SAC)
ø1,5 m; height 1,5 m (FAC)
Quiet Zone IEC/EN 61000-4-22 ø1,5 m; height 1,5 m (30 MHz -1 GHz)
ø1,0 m; height 1,0 m (1 GHz -6 GHz)
Measuring distances 3,0 m
Load capacity up to 5.000 kg; special turntable systems possible
Frequency range 9 kHz/ 26 MHz to 18 or 40 GHz

Performance & Compliance – Semi Configuration

Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4

Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

Full compliant immunity (EMS) according to IEC/EN 61000-4-3

Deviation FU 0/+6 dB for 12 of 16 test points (75%)
(26 MHz to 18 GHz) – guaranteed

Performance & Compliance – Fully Configuration

Full compliant emission (EMI) according to CISPR 16-1-4

Deviation FS NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation FS SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

Full compliant immunity (EMS) according to IEC/EN 61000-4-3

Deviation FU 0/+6 dB for 12 of 16 test points (75%) (26 MHz to 18 GHz) – guaranteed

Full compliant immunity (EMS) and emission (EMI) according to IEC/EN 61000-4-22

Standard Deviation SdB c ≤ 1,8 dB