SAC-3 / FAC-3 Transformer
Semi and fully anechoic 3,0 m EMC chamber, transformable combination
Semi and fully anechoic 3,0 m EMC chamber, transformable combination
The SAC-3/FAC-3 Transformer is Frankonia’s full compliant EMC testing solution at 3,0m measuring distance offering semi as well as fully conditions. This special solution focus on conditions with ground plane, as well as FAR conditions for table-top EUT tests with an optimized floor-absorber modification kit. The SAC-3/FAC-3 Transformer chamber is adapted for full compliant emissions and immunity testing with a traditional square design.
Overview |
EMI | CISPR 16-1-4 and ANSI C63.4, full compliant |
EMS | IEC/EN 61000-4-3, full compliant |
Test distance | 3,0m |
Volume | ø2,0 m as SAC Chamber ø1,5 m as FAC Chamber |
Special | Transformable test site from SAC to FAC |
Transformable from SAC to FAC test site
Cost-effective and high-performance solution for a 3,0 m measuring distance
SAC setup: QZ of ø2,0 m
FAC setup: QZ of ø1,5 m
Full compliant EMI/EMS
Upgradeable for E-Drive (load machine, BlueBox, battery test system)
Compact chamber design with advanced absorber lining
Outstanding performance with long-lasting Frankosorb® non-combustible absorbers
Turnkey solution
Useable for automotive and military standard tests
Frankosorb® optimized hybrid absorber lining with Ferrite F006, H600 and H1000
High-performance nano thin-film technology with proven long-term stability
Available material classifications:
non-combustible acc. to DIN EN 13501-1 class A2 – s1 d0, or
hardly inflammable acc. to DIN EN 13501-1 class B (alternative)
Emission
CISPR 11
CISPR 14
CISPR 15
CISPR 25
CISPR 32
MIL-STD 461
Immunity
IEC/EN 61000-4-3
ISO 11452
MIL-STD 461
Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.
Emission
CISPR 16-1-4
and/or ANSI C63.4
IEC/EN 61000-4-22
Immunity
IEC/EN 61000-4-3
IEC/EN 61000-4-22
Chamber Type | SAC-3 / FAC-3 Transformers |
External dimension | 9.680 x 6.530 x 6.000 mm (LxWxH) |
Quiet Zone | ø2,0 m; height 1,5 m (SAC) ø1,5 m; height 1,5 m (FAC) |
Quiet Zone IEC/EN 61000-4-22 | ø1,5 m; height 1,5 m (30 MHz -1 GHz) ø1,0 m; height 1,0 m (1 GHz -6 GHz) |
Measuring distances | 3,0 m |
Load capacity | up to 5.000 kg; special turntable systems possible |
Frequency range | 9 kHz/ 26 MHz to 18 or 40 GHz |
Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4
Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed
Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0/+6 dB for 12 of 16 test points (75%)
(26 MHz to 18 GHz) – guaranteed
Full compliant emission (EMI) according to CISPR 16-1-4
Deviation FS NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation FS SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed
Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0/+6 dB for 12 of 16 test points (75%) (26 MHz to 18 GHz) – guaranteed
Full compliant immunity (EMS) and emission (EMI) according to IEC/EN 61000-4-22
Standard Deviation SdB c ≤ 1,8 dB