SAC-10V
Semi-anechoic 10,0 m EMC chamber dedicated to Vehicle Tests per ECE R10
Semi-anechoic 10,0 m EMC chamber dedicated to Vehicle Tests per ECE R10
The SAC-10V chamber solutions are Frankonia’s full compliant and customizable EMC testing solutions at 10,0 m measuring distance offering various sizes of Quiet Zone (QZ) and are dedicated to automotive full vehicle testing with integrated dynamometer.
Due to the high grade of customization reflecting the demands of our customers, this semi anechoic chamber is adaptable in size and offers several configuration possibilities.
The SAC-10V solutions are either available with Frankosorb® hybrid absorber lining, or with unique Frankosorb® long-pyramid absorber lining. Identical performances can be offered using hybrid or long-pyramid absorbers.
Overview |
EMI | CISPR 16-1-4 and ANSI C63.4, full compliant CISPR 25 and CISPR 12, full compliant |
EMS | IEC/EN 61000-4-3, full compliant |
Test distance | up to 10,0m |
Volume | e.g. ø6,0 m |
Special | Hybrid or long-pyramid absorbers |
ECE R10.5 | Full compliant at 10,0 m with dynamometer |
Testing according to ECE R10.5 with an integrated dynamometer
Available with Frankosorb® long-pyramid, or hybrid absorbers
Full compliant EMI/EMS
Highly customizable solution for any kind of EMC testing
and limitless integration of individual applications
Adjustable anechoic chamber size, characteristics and configuration
due to different EUT requirements
Advanced absorber lining with long-lasting and non-combustible
Frankosorb® absorbers (Frankonia technology)
Specialized for ‘out-of-the-range’ EMC test environments
Useable for commercial and military standard tests
SAC-10V – Hybrid: Frankosorb® optimized hybrid absorber lining with Ferrite F006, H600, H1000, and Turbine H1300
SAC-10V – Pyramid: Frankosorb® optimized long-pyramid absorber lining with P2400
High-performance nano thin-film technology with proven long-term stability
Available material classifications:
non-combustible acc. to DIN EN 13501-1 class A2 – s1 d0, or
hardly inflammable acc. to DIN EN 13501-1 class B (alternative)
Emission
CISPR 11
CISPR 12
CISPR 14
CISPR 15
CISPR 25
CISPR 32
MIL-STD 461
ECE R10.5
Immunity
IEC/EN 61000-4-3
ISO 11451
ISO 11452
MIL-STD 461
RS101, RS102
RS103
ECE R10.5
Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.
Emission
CISPR 16-1-4
and/or ANSI C63.4
Immunity
IEC/EN 61000-4-3
Chamber Type | SAC-10VC-6H | SAC-10V-6/H | SAC-10V-6/P |
External dimension | 23.030 x 14.480 x 6.300 mm (LxWxH) | 22.580 x 15.980 x 8.700 mm (LxWxH) | 26.480 x 20.180 x 9.000 mm (LxWxH) |
Quiet Zone at 3,0 m | ø3,0 m | ø3,0 m | ø3,0 m |
Quiet Zone at 5,0 m | ø5,0 m | ø5,0 m | ø5,0 m |
Quiet Zone at 10,0 m | n/a | ø6,0 m | ø6,0 m |
Dynamometer | e.g., ø7,0 m | e.g., ø9,0 m | e.g., ø9,0 m |
Absorber lining | Hybrid | Hybrid | Long pyramid |
Load capacity | up to 80.000 kg; special turntable systems and dynamometer integration possible | ||
Specials | Highly adjustable to any vehicle typ, size and weight | ||
Frequency range | 9 kHz/ 26 MHz to 18 or 40 GHz |
Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4
Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed
Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0/+6 dB for 12 of 16 test points (75%)
(26 MHz to 18 GHz) – guaranteed
Full compliant emission (EMI) according to CISPR 25
(ALSE verification acc. to the long-wire method recommended)
Full compliant emission (EMI) according to CISPR 12 at 10,0 m test distance
Full compliant immunity (EMS) according to ISO 11452 and ISO 11451
Perfectly meets ECE R10.5 with dynamometer integration