More products
show

SAC-10/H Hybrid

Semi Anechoic 10m EMC Chamber with Hybrid Absorbers

The SAC-10/H chambers are Frankonia’s full compliant and customizable EMC testing solutions at 10,0 m measuring distance with a Quiet Zone (QZ) of ø3,0 m up to ø6,0 m and hybrid absorber layout. Due to the high grade of customization reflecting the demands of our customers, this semi anechoic chamber is adaptable in size and offers several configuration possibilities. The impressionable hybrid absorber layout achieves exceptional performance for emission measurements and immunity testing.

Overview
EMICISPR 16-1-4 and ANSI C63.4, full compliant
EMSIEC/EN 61000-4-3, full compliant
Test distanceup to 10,0m
Volumeø3,0 m up to ø6,0 m
SpecialHybrid Absorbers

Features

Frankosorb®hybrid absorber lining

Full compliant EMI/EMS

Highly customizable solution for any kind of EMC testing

and limitless integration of individual applications; as single or double test axis option

Notably adjustable anechoic chamber size, characteristics, and configuration

due to different EUT requirements

Advanced absorber lining with long-lasting and non-combustible Frankosorb® absorbers

(Frankonia technology)

Specialized for ‘out-of-the-range’ EMC test environments

Useable for automotive and military standard tests

Turnkey solution

Absorbers

Frankosorb® optimized hybrid absorber lining with Ferrite F006, H600, and H1000, or the Turbine absorbers H1300

High-performance nano thin-film technology with proven long-term stability

Available material classifications:
non-combustible acc. to DIN EN 13501-1 class A2 – s1 d0, or
hardly inflammable acc. to DIN EN 13501-1 class B (alternative)

Typical Product Standards

Emission

CISPR 11

CISPR 12

CISPR 14

CISPR 15

CISPR 25

CISPR 32

MIL-STD 461

Immunity

IEC/EN 61000-4-3

ISO 11451

ISO 11452

MIL-STD 461

RS101, RS102,

RS103

Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.

Typical Verification Standards

Emission

CISPR 16-1-4

and/or ANSI C63.4

Immunity

IEC/EN 61000-4-3

Typical Specifications

Chamber Type SAC-10-3/H SAC-10-4/H
External dimension 18.380 x 12.830 x 8.550 mm (LxWxH) 19.280 x 13.280 x 8.550 mm (LxWxH)
Quiet Zone at 3,0m ø3,0 m ø3,0 m
Quiet Zone at 5,0m ø3,0 m ø4,0 m
Quiet Zone at 10,0m ø3,0 m ø4,0 m
 
Chamber Type SAC-10-5/H SAC-10-6/H
External dimension 21.080 x 15.080 x 8.550 mm (LxWxH) 21.680 x 15.680 x 8.700 mm (LxWxH)
Quiet Zone at 3,0m ø3,0 m ø3,0 m
Quiet Zone at 5,0m ø5,0 m ø5,0 m
Quiet Zone at 10,0m ø5,0 m ø6,0 m
 
Load capacity up to 80.000 kg; special turntable systems and dynamometer integration possible
Frequency range 9 kHz/ 30 MHz to 18 GHz or 40 GHz)

Performance & Compliance

Full compliant emission (EMI) according to CISPR 16-1-4 and ANSI C63.4

Deviation NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

Full compliant immunity (EMS) according to IEC/EN 61000-4-3

Deviation FU 0/+6 dB for 12 of 16 test points (75%)
(26 MHz to 18 GHz) – guaranteed