MIL-STD Chamber

Military Testing Chamber for Vehicles and large EUT’s

Overview
EMIMIL-STD 461 / DO-160
EMSMIL-STD 461 / DO-160
Test distance1,0 m
VolumeNo test volume
SpecialAdapted to any EUT type and size

The MIL-STD Chamber is Frankonia’s large chamber solution at 1,0 m measuring distance according to MIL-STD 461 adapted for radiated emission and immunity tests for large EUT’s or vehicles.

Features

High performance solution for military testing

Advanced absorber lining with long-lasting short P600

or P900 Frankosorb® absorbers (Frankonia technology)

Full compliant EMI/EMS

Highly customizable solution for any kind of EMC testing

and limitless integration of individual applications

Adjustable chamber size, characteristics

and configuration due to different EUT requirements

Turnkey solution

Typical Product and Verification Standards

Emission

MIL-STD 461

DO-160

Immunity

MIL-STD 461

DO-160

Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.

Typical Specifications

Chamber Type MIL-STD Chamber
Size To be defined acc. to EUT type and size
Measuring distances 1,0 m
Load capacity up to 80,0 tons; special turntable systems and integrations possible
Frequency range 9 kHz/ 26 MHz to 40 GHz

Performance & Compliance

Full compliant emission (EMI) according to MIL-STD 461

Full compliant immunity (EMS) according to MIL-STD 461

Absorption at normal incidence:
80 MHz to 250 MHz ≥ 6 dB, as per standard requirements
above 250 MHz ≥ 10 dB, as per standard requirements

Menu

Copyrighted Image