More products
show

CTC

Component Testing Chamber

The CTC is Frankonia’s customized component testing chamber solution for commercial immunity testing as well as automotive and military components. This chamber solution is adapted for full compliant tests of automotive components according to CISPR 25 and ISO 11452 at 1,0 m test distance, as well as full compliant testing according to MIL-STD 461 and DO-160 at 1,0 m test distance. Further to that, the chamber meets full compliance requirements according to IEC EN 61000-4-3 for a 3,0 m measuring distance. The typical chamber is lined with ferrite absorbers and with and optimized Frankosorb® Hybrid absorber layout.

Overview

EMICISPR 25
MIL-STD 461 / DO-160

EMSISO 11452
MIL-STD 461 / DO-160
IEC EN 61000-4-3
Test distance1,0 m, 3,0 m

Features

Compact chamber solution for component testing according to CISPR 25 & MIL-STD 461 / DO-160

Full compliant EMS solution for commercial products per IEC EN 61000-4-3

Compact chamber design with advanced absorber lining with long-lasting Frankosorb® absorbers (Frankonia technology)

Turnkey solution

Absorbers

Frankosorb® optimized hybrid absorber lining with Ferrite F006, and H450

Available material classifications:
non-combustible acc. to DIN EN 13501-1 class A2 – s1 d0, or
hardly inflammable acc. to DIN EN 13501-1 class B (alternative)

Typical Product Standards

Emission

CISPR 25

MIL-STD 461 / DO-160

Immunity

ISO 11452

MIL-STD 461 / DO-160

IEC EN 61000-4-3

Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.

Typical Verification Standards

Emission

CISPR 25

MIL-STD 461 / DO-160

Immunity

IEC EN 61000-4-3

Typical Specifications

Chamber Type CTC
External dimension 8.480 x 5.485 x 3.750 mm (LxWxH)
Setup Table setup, floor standing
Test distance 1,0 m, 3,0 m
Load capacity up to 2.000 kg
Frequency range 9 kHz to 18 or 40 GHz

Performance & Compliance

Full compliant emission (EMI) according to CISPR 25 (ALSE verification acc. to the long-wire method)

Full compliant emission (EMI) according to MIL-STD 461 / DO-160

Full compliant immunity (EMS) according to ISO 11452

Full compliant immunity (EMS) according to MIL-STD 461 / DO-160

Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0/+6 dB for 12 of 16 test points (75%)
(26 MHz to 18 GHz) – guaranteed