CHC

Pre-compliant 3m Compact EMC Chamber

Overview
EMIPre-compliant
EMSIEC/EN 61000-4-3, full compliant
Test distance3,0 m
Volumeø1,2 m
SpecialCompact immunity test chamber

The CHC is Frankonia’s compact hybrid chamber solution at 3,0 m measuring distance with a Quiet Zone (QZ) of ø1,2 m. The CHC is an upgradable solution and can transform from a semi anechoic chamber configuration with ground plane to a fully anechoic chamber configuration with floor absorbers. It is an optimal solution for both pre-compliance emission tests and full compliance immunity tests at 3,0 m measuring distance.

The extended version of the CHC, called CHC-L, includes an absorber-lined partition wall that offers the feature for housing and storing RF power amplifiers, antennas, and floor absorbers inside the chamber.

Features

Full compliant EMS and pre-compliant EMI solution

Cost effective solution for EMS measurements

Compact chamber design with advanced absorber lining

with long-lasting Frankosorb® absorbers (Frankonia technology)

Upgradable to FAC for free-space measurements

Turnkey solution

Typical Product Standards

Emission

Pre-compliance

from 30 MHz
to 1 GHz

Immunity

IEC/EN 61000-4-3

Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.

Typical Verification Standards

Emission

CISPR 16-1-4

Immunity

IEC/EN 61000-4-3

Typical Specifications

Chamber CHC CHC-L 
External dimension 7.355 x 3.755 x 3.300 mm (LxWxH) 8.255 x 3.755 x 3.300 mm (LxWxH)
Quiet Zone ø1,2 m
Measuring distances 3,0 m
Load capacity up to 2,0 tons; special turntable systems possible
Frequency range 9 kHz/ 30 MHz to 18 GHz (option 40 GHz)

Performance & Compliance

Pre-compliant emission (EMI) according to CISPR 16-1-4

Full compliant immunity (EMS) according to IEC/EN 61000-4-3

Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points
(26/ 80 MHz to 18 GHz) – guaranteed

Menu

Copyrighted Image