CHC Plus
Pre-compliant 3,0 m Compact Hybrid Chamber
Pre-compliant 3,0 m Compact Hybrid Chamber
The CHC Plus is Frankonia’s version of the compact hybrid chamber solution at 3,0 m measuring distance with a Quiet Zone (QZ) of ø1,2 m that meets the SVSWR verification on emission testing. It is an optimal solution for both pre-compliance emission tests and full compliance immunity tests at 3,0 m measuring distance.
Overview |
EMI | CISPR 16-1-4 Pre-compliant 30 MHz to 1 GHz, and full compliant 1 GHz to 18 GHz |
EMS | IEC/EN 61000-4-3, full compliant |
Test distance | 3,0m |
Volume | ø1,2 m |
Special | Compact immunity test chamber, full compliant for emission >1 GHz |
Full compliant EMS
Pre-compliant EMI solution from 30 MHz to 1 GHz (no height scan possible)
Full compliant EMI solution from 1 GHz to 18 GHz (no height scan necessary)
Cost effective solution for EMS measurements, paired with EMI measurements in the GHz range
Compact chamber design with advanced absorber lining with long-lasting Frankosorb® absorbers (Frankonia technology)
Turnkey solution
Frankosorb® optimized hybrid absorber lining with Ferrite F006, and H450
High-performance nano thin-film technology with proven long-term stability
Available material classifications:
non-combustible acc. to DIN EN 13501-1 class A2 – s1 d0, or
hardly inflammable acc. to DIN EN 13501-1 class B (alternative)
Emission
Pre-compliant
from 30 MHz
to 1 GHz
Full compliant
from 1 GHz
to 18 GHz
Immunity
IEC/EN 61000-4-3
Note:Â We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.
Emission
CISPR 16-1-4
Immunity
IEC/EN 61000-4-3
Chamber | CHC Plus | CHC Plus L |
External dimension | 7.880 x 4.880 x 3.450 mm (LxWxH) | 8.480 x 5.480 x 3.900 mm (LxWxH) |
Quiet Zone | ø1,2 m | ø1,2 m |
Turntable | ø1,2 m | ø2,0 m |
Measuring distances | 3,0 m | |
Load capacity | up to 2.000 kg; special turntable systems possible | |
Frequency range | 9 kHz/ 30 MHz to 18 GHz or 40 GHz |
Pre-compliant emission (EMI) according to CISPR 16-1-4 from 30 MHz to 1 GHz
Full compliant emission (EMI) according to CISPR 16-1-4 from 1 GHz to 18 GHz
Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0/+6 dB for 12 of 16 test points (75%)
(26 MHz to 18 GHz) – guaranteed