CHC Plus

Pre-compliant 3m Compact EMC Chamber

Overview
EMICISPR 16-1-4, Pre-compliant 30 MHz to 1 GHz
and full compliant 1 GHz to 18 GHz
EMSIEC/EN 61000-4-3, full compliant
Test distance3,0m
Volumeø1,2 m
SpecialCompact immunity test chamber, full compliant for emission >1 GHz

The CHC Plus is Frankonia’s version of the compact hybrid chamber solution at 3,0m measuring distance with a Quiet Zone (QZ) of ø1,2m that meets the SVSWR verification. The CHC Plus is an upgradable solution and can transform from a semi anechoic chamber configuration with ground plane to a fully anechoic chamber configuration with floor absorbers. It is an optimal solution for both pre-compliance emission tests and full compliance immunity tests at 3,0m measuring distance.

Features

Full compliant EMS

Pre-compliant EMI solution from 30 MHz to 1 GHz (no height scan possible)

Full compliant EMI solution from 1 GHz to 18 GHz (no height scan necessary)

Cost effective solution for EMS measurements, paired

with EMI measurements in the GHz range

Compact chamber design with advanced absorber lining

with long-lasting Frankosorb® absorbers (Frankonia technology)

Upgradable to FAC for free-space measurements

Turnkey solution

Typical Product Standards

Emission

Pre-compliant

from 30 MHz
to 1 GHz

Full compliant

from 1 GHz
to 18 GHz

Immunity

IEC/EN 61000-4-3

Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.

Typical Verification Standards

Emission

CISPR 16-1-4

Immunity

IEC/EN 61000-4-3

Technical specifications

Chamber CHC Plus CHC Plus L
External dimension 7.355 x 3.755 x 3.300 mm (LxWxH) 7.580 x 4.655 x 4.350 mm (LxWxH)
Quiet Zone ø1,2 m
Turntable ø1,2 m ø2,0 m
Measuring distances 3,0 m
Load capacity up to 2,0 tons; special turntable systems possible
Frequency range 9 kHz/ 30 MHz to 18 GHz (option 40 GHz)

Performance & Compliance

Pre-compliant emission (EMI) according to CISPR 16-1-4 from 30 MHz to 1 GHz

Full compliant emission (EMI) according to CISPR 16-1-4 from 1 GHz to 18 GHz

Full compliant immunity (EMS) according to IEC/EN 61000-4-3

Deviation FU 0 dB/+6 dB at 75 % of 16 measuring points
(26/ 80 MHz to 18 GHz) – guaranteed

Menu