The CHC Plus was a logical development out of our pre-compliance test chamber range having in mind to provide a chamber that is just pre-compliance for emission measurements from 30 MHz to 1 GHz, but is fully compliant from 1 GHz to 18 GHz, as well as immunity from 30 MHz to 18 GHz.
The CHC Plus is the ideal alternative for customers focusing to immunity tests, but adding the possibility for full compliant emission measurements in the higher frequency range. Without considering a height scan, the CHC Plus is compact and therefore a real cost saver.
Performance guaranteed:
Emission acc.to CISPR 16-1-4:
Quiet Zone: Ø1,2m (2m H) at 3m test distance
Pre-compliance from 30 MHz to 1 GHz, because of limited height scan
Full compliant from 1 GHz to 18 GHz
Immunity acc.to EN/IEC 61000-4-3:
Uniform field: 1,5 x 1,5m at 3m test distance
Full compliant from 30 MHz to 18 GHz
Feature: Special floor absorber layout with same absorbers for EMI and EMS
For further details, please contact us.