PMS 1084

The PMS 1084 is in the standard version a 2-channel RF-Power Meter for the frequency range from 100 kHz up to 6 GHz or from 10 kHz to 500 MHz (PMS 1084 B). The measuring range reaches from –60 dBm to +20 dBm. It is possible to upgrade the PMS 1084 up to max. 4 measuring channels at any time. The measured values can be displayed via a software which is included in the delivery or via the control software of an automated test system. For the integration of the PMS 1084 into a remote-controlled test system it is equipped with serial and USB interface. Hence the PMS 1084 is very good suitable for the automated measurement of forward and reverse power in immunity test systems acc. to IEC/EN 61000-4-3 / -6. It is available for the installation into 19”-rack or as stand-alone unit.

Technical specifications PMS 1084 PMS1084B
Number of channels 2 (standard); up to 4 (option)
Frequency range 2 x Input-Module LF 10 kHz – 500 MHz
Frequency range 2 x Input-Module HF 100 kHz – 6 GHz
Measuring range -60 dBm to +20 dBm (10 kHz ≤ f ≤ 4 GHz)
-45 dBm to +20 dBm (4 GHz < f ≤ 6 GHz)
Accuracy ± 1 dB (0.5 dB typical)
Resolution 0.1 dB
Integration time 0.5 – 200 ms (firmware)
Max. input level +27 dBm (= 500mW)
VSWR up to 2GHz -> 1:1.15
2 – 4 GHz -> 1:1.25
4 – 6 GHz -> 1:1.35
RF-Impedance 50 Ω
Interface (PC) USB, RS232 (9-pol Sub D. female)
Input N-type female connector
Dimensions (DxWxH) 172 x 482.6 x 44.3 mm
Weight approx. 2.5 kg
Power supply 115/230 V
Accessories included Power cord, USB cable, application software, user manual
Options PMS 1084 PMS1084B
PMS-CHA Expansion of 1 measuring channel (max. up to 4 channels); 100 kHz to 6 GHz
PMS-CHAB Expansion of 1 measuring channel (max. up to 4 channels); 10 kHz to 500 MHz

The PMS 1084 is in the standard version a 2-channel RF-Power Meter for the frequency range from 100 kHz up to 6 GHz or from 10 kHz to 500 MHz (PMS 1084 B). The measuring range reaches from –60 dBm to +20 dBm. It is possible to upgrade the PMS 1084 up to max. 4 measuring channels at any time. The measured values can be displayed via a software which is included in the delivery or via the control software of an automated test system. For the integration of the PMS 1084 into a remote-controlled test system it is equipped with serial and USB interface. Hence the PMS 1084 is very good suitable for the automated measurement of forward and reverse power in immunity test systems acc. to IEC/EN 61000-4-3 / -6. It is available for the installation into 19”-rack or as stand-alone unit.

Technical specifications PMS 1084 PMS1084B
Number of channels 2 (standard); up to 4 (option)
Frequency range 2 x Input-Module LF 10 kHz – 500 MHz
Frequency range 2 x Input-Module HF 100 kHz – 6 GHz
Measuring range -60 dBm to +20 dBm (10 kHz ≤ f ≤ 4 GHz)
-45 dBm to +20 dBm (4 GHz < f ≤ 6 GHz)
Accuracy ± 1 dB (0.5 dB typical)
Resolution 0.1 dB
Integration time 0.5 – 200 ms (firmware)
Max. input level +27 dBm (= 500mW)
VSWR 1.15
RF-Impedance 50 Ω
Interface (PC) USB, RS232 (9-pol Sub D. female)
Input N-type female connector
Dimensions (DxWxH) 172 x 482.6 x 44.3 mm
Weight approx. 2.5 kg
Power supply 115/230 V
Accessories included Power cord, USB cable, application software, user manual
Options PMS 1084 PMS1084B
PMS-CHA Expansion of 1 measuring channel (max. up to 4 channels); 100 kHz to 6 GHz
PMS-CHAB Expansion of 1 measuring channel (max. up to 4 channels); 10 kHz to 500 MHz