More products
show

FAC-3

Fully anechoic 3,0 m EMC chamber for table-top EUT’s

The FAC-3 is Frankonia’s fully anechoic chamber solution at 3,0 m measuring distance on table-top positioned EUT’s. It is designed as full compliant chamber for measurements under free-space conditions and is based on CISPR 16-1-4 as a test site without ground plane. Without the reflections from the floor, a height scan is no longer necessary. With its specific requirements for the test site, Frankonia’s FAC-3 is supremely prepared to meet our customers’ demands.

Overview
EMICISPR 16-1-4 and IEC/EN 61000-4-22, full compliant
EMSIEC/EN 61000-4-3 and IEC/EN 61000-4-22, full compliant
Test distance3,0m
Volumeø1,5 m (H=1,5 m)
SpecialFree-space test environment for table-top EUT’s

Features

Test site for table top EUT’s

Full compliant EMI/EMS

Cost effective solution for free-space measurements

Compact chamber design with advanced absorber lining

with long-lasting Frankosorb® absorbers (Frankonia technology)

Turnkey solution

Absorbers

Frankosorb® optimized hybrid absorber lining with Ferrite F006, and H600

High-performance nano thin-film technology with proven long-term stability

Available material classifications:
non-combustible acc. to DIN EN 13501-1 class A2 – s1 d0, or
hardly inflammable acc. to DIN EN 13501-1 class B (alternative)

Typical Product Standards

Emission

e.g., CISPR 14

ETSI

Immunity

IEC/EN 61000-4-3

Note: We advise you about details on the individual standards and define the right anechoic chamber solution that meets your needs.

Typical Verification Standards

Emission

CISPR 16-1-4

IEC/EN 61000-4-22

Immunity

IEC/EN 61000-4-3

IEC/EN 61000-4-22

Typical Specifications

Chamber FAC-3
External dimension 8.705 x 4.655 x 3.750 mm (LxWxH)
Quiet Zone  ø1,5 m (H=1,5 m); table-top EUT tests
Turntable ø1,5 m
Measuring distances 3,0 m
Load capacity up to 2.000 kg; special turntable systems possible
Frequency range 9 kHz/ 30 MHz to 18 or 40 GHz

Performance & Compliance

Full compliant emission (EMI) according to CISPR 16-1-4

Deviation FS NSA ±3,5 dB (30 MHz to 1 GHz) – guaranteed
Deviation FS SVSWR +5,5 dB (1 GHz to 18 GHz) – guaranteed

Full compliant immunity (EMS) according to IEC/EN 61000-4-3
Deviation FU 0/+6 dB for 12 of 16 test points (75%)
(26 MHz to 18 GHz) – guaranteed

Full compliant immunity (EMS) and emission (EMI) according to IEC/EN 61000-4-22
Standard deviation SdB c ≤ 1,8 dB